The other PDCM version, and the cabinet boards it connects.
PDCM versions:
- 5124369 — PDCM for M33 Optimizado cabinets
ARCA 2 cabinet boards:
- 5124409 — CPU M34 main board
- 5124336 — PB base input and output board
- 5124337 — CPU main control board
- 5124400 — PCGONG intercom and gong board
- 5124430 — EXT1 extension board
Potensi supplies the Orona elevator PDCM distribution board 5124416, the Orona elevator PCB board and the cabinet boards around it. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
ポテンシを選ぶ理由
- 99% の市場カバレッジ: 弊社では、市場で入手可能なエレベーター用スペアパーツを約99%分供給可能です。.
- 確かな品質保証: 当社は、純正で信頼性の高いエレベーター用部品を提供しています。.
- 専門家による身元確認の支援: 型番または製品の写真をお送りいただければ、適切な部品をご案内いたします。.
- 国際配送: 当社は、エレベーターの保守プロジェクトにおいて、迅速かつ確実な国際配送をサポートしています。.
よくある質問
Q1: What does the PDCM board do?
A: Orona’s own parts list describes it as the signal distribution board of the control cabinet, and that is exactly its job. It takes the cabinet signals and passes them on to the boards and the terminal blocks, so the CPU does not wire to the field directly. That is why a fault on it tends to show in more than one circuit rather than in a single function.
Q2: Are there several PDCM versions?
A: Yes. Orona lists a PDCM that serves all apparatus except the Optimizado and the normal M33, and a separate PDCM for M33 Optimizado cabinets at 5124369. The boards look similar and both are called PDCM, but they suit different cabinets. Order by the full number on the PCB, not by the code name alone.
Q3: Is 5124416 the same as 5124416-01?
A: The base number 5124416 identifies the board, and the -01 suffix is the assembly number distributors print alongside it. Both are used for this PDCM, and you will see either form on invoices and labels. Send us a photo of the label and we will confirm which one we ship.
Q4: Does it need programming when replaced?
A: No parameters are loaded into this board. It is a distribution board, and the lift settings live in the CPU and the energy manager. What matters at replacement is the connector layout and the position of every plug, because the cabinet will not run if one is misplaced. Keep the old board next to the new one while you transfer the plugs.
Q5: Which cabinet generation uses it?
A: 5124416 sits in the 51244xx range that Orona used through the ARCA II generation, next to the CPU M34 at 5124409. The ARCA 3 cabinets carry numbers in the 51245xx range and use different boards. If your cabinet is an ARCA 3, send us the old board number before ordering.
Q6: What should I send before ordering?
A: A photo of the old board, front and back, with the number and every connector visible. Tell us the cabinet type, and whether the lift is a standard machine or an M33 Optimizado, because that is what separates the two PDCM versions. With that we confirm the number before dispatch.