説明
製品情報
関連モデルおよび代替モデル
Other BPP landing board drawings:
- 2664.65 MOD (333333) — BPP for the CMC4 controller
- 2666.34 MOD (222222) — BPP+ board for CMC4+
- 2666.37 MOD (222232) — same drawing, other MOD
Boards of the same cabinet:
- 2665.67 UCM2 — main control board
- 2665.79 UCV — CMC4+ control board
- UCC2 — car panel board
Potensi supplies the TKE elevator landing board UCP-BPP 2666.37, the TKE LOP board and the other TKE PCB boards of the CMC4+ cabinet. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
ポテンシを選ぶ理由
- 99% の市場カバレッジ: 弊社では、市場で入手可能なエレベーター用スペアパーツを約99%分供給可能です。.
- 確かな品質保証: 当社は、純正で信頼性の高いエレベーター用部品を提供しています。.
- 専門家による身元確認の支援: 型番または製品の写真をお送りいただければ、適切な部品をご案内いたします。.
- 国際配送: 当社は、エレベーターの保守プロジェクトにおいて、迅速かつ確実な国際配送をサポートしています。.
よくある質問
Q1: What does this landing board do?
A: It is the landing operating panel board, the board that sits behind the hall buttons on each floor. TKE builds this part of the system in a decentralized way: the board integrates the push buttons and the direction arrows itself and carries its own microprocessor. It registers the call on that floor and reports it to the controller over the floor bus, so one board serves one landing rather than one board serving the whole building.
Q2: Is this the cabin board or a landing board?
A: It is a landing board, mounted in the hall call panel on the floor. The car side uses a different board, the UCC2, with a different connector set and a different function. Mixing the two is a common ordering mistake, so check the mounting position before you compare numbers.
Q3: What do the numbers on the label mean?
A: The label carries four separate pieces of information, and all four matter. UCP-BPP is the board designation and V1.14 is its version; 2666.37 is the drawing number; MOD (111121) is the variant code; UCP+ CMC4+ names the controller family the board belongs to. Quote them all when you ask for a price, because the same board designation exists in several versions.
Q4: Can I fit a board with a different MOD code?
A: Not safely in every installation. The same drawing appears with different MOD codes, and neighbouring drawings carry other variants: 2666.37 is also seen as MOD (222232), and 2666.34 is offered as the BPP+ board for CMC4+. Different MOD versions are not interchangeable in all systems, so match the code printed on the board you take out rather than the drawing number alone.
Q5: How many boards do we need for one lift?
A: One per landing, because each floor panel carries its own board. Count the floors served, then note whether each panel has both up and down arrows or a single button, as the two configurations use different panels. For a group of lifts, each lift has its own set of landing panels.
Q6: What do you need from me before dispatch?
A: A clear photo of the label showing the designation, the MOD code and the order number, plus a photo of the connectors on the back. Tell us the floor count and the controller type on the cabinet nameplate. The board is supplied on its own; the button inserts, the panel plate and the ribbon cables are separate items.