説明
製品情報
関連モデルおよび代替モデル
Other versions of the LVPB, and the Otis boards that work with it.
Other LVPB versions:
- GCA26800PM1 — 230 V AC version
- GCA26800PM3 — later version
- GCA26800PM10 — listed with PM1
- GAA26800PM1 / GBA26800PM1 — same board, other prefixes
Boards and assemblies around it:
- GBA29502C10 — GECB-LV + LVPB combined print, 230 V
- GBA26800NR — GECB-LV control board
Potensi supplies the Otis elevator LVPB power board GCA26800PM2 and the Otis GECB-LV power supply range. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
ポテンシを選ぶ理由
- 99% の市場カバレッジ: 弊社では、市場で入手可能なエレベーター用スペアパーツを約99%分供給可能です。.
- 確かな品質保証: 当社は、純正で信頼性の高いエレベーター用部品を提供しています。.
- 専門家による身元確認の支援: 型番または製品の写真をお送りいただければ、適切な部品をご案内いたします。.
- 国際配送: 当社は、エレベーターの保守プロジェクトにおいて、迅速かつ確実な国際配送をサポートしています。.
よくある質問
Q1: What does the LVPB supply?
A: Otis defines it as the source of every DC rail in the GECB-LV system, and the basic data lists four outputs. 48 V for the safety chain and drive at 3.2 A, 48 V for the car at 3.7 A, 7.2 A in the higher configuration. 30 V at 1.2 A for the serial link master and CAN group, and 12 V at 1.2 A for the encoder, the 5 V and 3.3 V logic and the car CAN.
Q2: What does a failing board look like on site?
A: A controller that does not start at all, one that restarts, or communication faults between boards that move when the cabinet warms up. Battery symptoms belong here too, because charging runs through this board: the charge symbol stays on Fault, or the battery never reaches full. Check the P-LVPB1 plug and the battery itself first, since a loose connector or a dead battery gives the same picture.
Q3: PM2, PM1, PM3 or PM10. Which one do I order?
A: They are versions of the same LVPB board, and the version has to match what the cabinet expects. PM1 is documented by distributors as the 230 V AC version; PM3 and PM10 sit alongside it in the same spare parts lists. Read the PM number off the failed board, and send the cabinet type with it, because the number is the only reliable identifier on these boards.
Q4: Does the board come programmed?
A: The LVPB is a power board, so it carries no lift parameters and no car configuration. What it does carry is a hardware version, and that is what has to match. We confirm the version and the supply state of every board before dispatch rather than promising that it runs as it arrives.
Q5: My board is fixed to the control board. Is it one part?
A: Sometimes. Otis mounts the GECB-LV vertically onto the LVPB with a sheet metal clamp, and some cabinets are supplied as one combined print, such as GBA29502C10 for the 230 V version. If the two boards are clamped together with no separate part number on the lower board, quote the assembly number. Send a photo of the pair and we will tell you which level to order.
Q6:注文する前に何を送ればよいですか?
A: A clear photo of the board, front and back, with the GCA number and the PM version readable. The cabinet type or the controller label, and the battery voltage and count if the site runs on battery rescue. Whether the old board failed on its own or took other boards with it, since a shorted rail often damages more than one card.