説明
製品情報
関連モデルおよび代替モデル
Other TKE inverter boards, and the control boards that work with the drive.
TKE inverter and drive boards:
TKE control boards:
- 65100004029 — MC1 HV2 main board
- 66200009274 — RMB3 HV1 relay board
- 6510053680 — PC MS 2 board
Potensi supplies the TKE elevator inverter main board MNCU-8C, the TKE elevator drive board and the TKE PCB board range around it. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
ポテンシを選ぶ理由
- 99% の市場カバレッジ: 弊社では、市場で入手可能なエレベーター用スペアパーツを約99%分供給可能です。.
- 確かな品質保証: 当社は、純正で信頼性の高いエレベーター用部品を提供しています。.
- 専門家による身元確認の支援: 型番または製品の写真をお送りいただければ、適切な部品をご案内いたします。.
- 国際配送: 当社は、エレベーターの保守プロジェクトにおいて、迅速かつ確実な国際配送をサポートしています。.
よくある質問
Q1: What does the MNCU-8C board do?
A: It is the main board of the inverter, the unit that converts the supply into the voltage and frequency the hoisting motor needs. The board carries the control electronics of that unit, so the drive’s own diagnostics and its output control run through it. It is a drive board, not the lift controller: when it fails the controller is still alive, but the motor gets no drive.
Q2: Is it the same as an MC1 or MC2 board?
A: No. MC1 and MC2 are controller boards, and this one belongs to the inverter section. They are different parts in different places in the cabinet, and one cannot stand in for the other. If you are not sure which section your board comes from, send us a photo of the cabinet with the board in place.
Q3: Does the revision matter?
A: Yes. The board is listed in more than one revision, and Rev 2.0 is the one most distributors carry. A different revision may not behave like the board you are taking out, even where the marking looks the same. Read the revision printed next to the marking and tell us both before ordering.
Q4: Which TKE inverters use this board?
A: The public listings for MNCU-8C do not name the drive families, so we will not guess at them. What identifies it is the marking on the board, the revision, and the drive label in the cabinet. Send us those photos and we will confirm the fit for your installation.
Q5: The drive trips and the lift stops. How do I know the board is at fault?
A: Note the fault code the drive displays first, because it points at the section that failed. Check the supply and the motor connections before the board: a loose power terminal or a motor insulation fault produces the same stop. If the supply and the motor are sound and the code keeps returning, the main board is the next suspect.
Q6: What should I send before ordering?
A: A photo of the old board, front and back, with the marking and the revision readable. A photo of the drive label, and the fault codes the drive has stored. With those three we confirm the board, the revision and the fit before dispatch.