TKE Landing Panel Board BPP 2664.65 MOD (333333)

BPP 2664.65, TKE part 10078815, is the landing operating panel board of the CMC4 and CMC4+ control systems. It carries the landing call buttons and passes the call to the main controller over the panel link. One board sits in each landing panel, behind the button plate. MOD (333333) is the variant code printed after the model.

Share it
  1. POTENSI business type is B2B not B2C, so it’s better to buy from your local distributor if you are an end user. Our business is only for local wholesalers/agents.
  2. You can try to contact our service department firstly if you are a big local elevator maintenance company with your own technician, then we will consider whether we can go on together or not.
  3. We are not your target supplier if you only focus on the lower price, ignoring the products, because POTENSI always puts Products and Services in first position.
  4. If you are searching for a long-term, reliable and professional elevator products supplier, please don't hesitate to REGISTER to become our member. You will receive great support and benefits.
  1. Quality Insurance
    100% New and from original manufacturers or their direct suppliers.
  2. Multi-brand Available Parts
    More than 200K multi-brand spare parts are available for any elevator brand.
  3. Speed & Flexibility
    Within 3 hours of feedback, 4 days package times for 10k products, 5 days ship out all.
  4. After-sales Insurance & Safety
    12-month warranty and free return if we send the wrong products.
  5. Maximum savings for the shipping cost
    ONE-STOP-SHOP saves time and shipping costs by purchasing all your parts from one source.

Whether you are a wholesaler or even maintenance company, you will find POTENSI is the ONE-STOP-SHOP for all the parts you need.

At POTENSI, our focus is to help you access to all kind of clients or all brand elevator easily with our 21 years experience in China elevator industry.

POTENSI mission is to help you to succeed and enhance building safety worldwide with top-quality elevator parts and outstanding service.

Delivery speed is our strength, but what make us different from everyone else is our multi-brand offering. Purchasing from POTENSI is as easy as it gets with 200K+ multi-brand parts.

Our web shop is open 24hours, 7days a week. Once you registered as our member, you will get many great benefits and you are able to find the part you need with any code and get our VIP service by sales specialist.

To ensure high quality, POTENSI provide parts only by original equipment manufacturers or their direct suppliers. You cooperate with POTENSI , you get the insurance of succeed when you are facing your customers.

Description

Product Information

Feature Specification
Model Number BPP 2664.65 MOD (333333)
Also Written As BPP 2664.65, BPP2664.65, 10078815, BPP-CMC4 board, LOP PCB, landing push button PCB
Brand TKE
Product Type Landing operating panel board (PCB)
Function Carries the landing call buttons and reports the call to the main controller
Used On TKE CMC4 and CMC4+ control systems, landing panels
Compatibility CMC4 family, MOD (333333) variant; 10079794 BPP+ is another version

Related & Alternative Models

The BPP board in its other version, and the boards of the same CMC4 panels.

BPP board versions:

  • 10079794 — BPP+ CMC4 PCB, another version

Boards in the same CMC4 panels:

  • 1026638301 — UCM-CMC4 main control board
  • UCC-CMC4 — car controller board
  • 2665.13 MOD (444454) — BMC panel board

Potensi supplies the TKE landing panel board BPP 2664.65 MOD (333333) and the TKE CMC4 board range around it. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.


Why Choose Potensi?

  • 99% Market Coverage: We can supply nearly 99% of elevator spare parts on the market.
  • Genuine Quality Assurance: We provide genuine and reliable elevator components.
  • Expert Identification Support: Send us the model number or product photos, and we can help confirm the correct part.
  • Global Shipping: We support fast and reliable international delivery for elevator maintenance projects.

FAQ

Q1: What does this board do?

A: It is the board inside a landing operating panel: the landing call buttons connect to it, and it passes the call to the main controller. In the CMC4 arrangement the landing panels work as decentralised units on a serial link rather than as a bundle of wires back to the controller. That is why a single failed landing panel can be swapped without touching the rest of the installation.

Q2: What is MOD (333333)?

A: It is the variant code printed after the model number, and it identifies the build of the board rather than the model itself. Two boards can both read 2664.65 and still carry different variant codes, which means different options or a later build. Quote the full line as it appears on the PCB, MOD code included, because the model alone does not pin the part down.

Q3: Does it fit both CMC4 and CMC4+?

A: The board belongs to the CMC4 family, and the CMC4+ generation has its own BPP part numbers, such as 10079794. The two generations look similar in the panel and do not always interchange, so the system generation decides which one is right. Tell us which controller the building runs and we will confirm against the part numbers we hold.

Q4: What does a failed board look like?

A: One landing at a time: the call button does not register, the call is registered and never cleared, or the button lights permanently. The rest of the landings keep working, which is the clue that the fault is in that panel rather than in the controller. Before replacing anything, look at the panel wiring and the button itself, since a stuck button gives the same result as a failed board.

Q5: How many do I need?

A: One board per landing panel, so a building with eight floors and a panel at each has eight of them. Panels at the top and bottom often carry a different button layout, but the board behind them is the same item per panel. Stock one spare for the busiest landing rather than one per floor: failures usually repeat where the traffic is.

Q6: What should I send with the request?

A: A photo of the board with the BPP number and the MOD code readable, front and back. The number of landings, and whether the panels are the flat CMC4 type or the CMC4+ type. The fault as it appears on site, and whether the panel is complete or you only need the PCB.