Description
Product Information
Related & Alternative Models
The other MCINV modules, and the boards it connects to.
Other MCINV modules:
- MCINV5SL — previous version, replaced by MCINV6S
- MCINV4 — earlier version, also replaced by MCINV6S
- MCINV3 — earliest module of the range
Modules it connects to:
- MCP7S — main controller board
- INT6S — parallel signal interface module
- MEED6S — magnetic limit module
- M4RS — relay and signal expansion
Potensi supplies the TKE inverter control module MCINV6S and the TKE MCINV drive range around it. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
Why Choose Potensi?
- 99% Market Coverage: We can supply nearly 99% of elevator spare parts on the market.
- Genuine Quality Assurance: We provide genuine and reliable elevator components.
- Expert Identification Support: Send us the model number or product photos, and we can help confirm the correct part.
- Global Shipping: We support fast and reliable international delivery for elevator maintenance projects.
FAQ
Q1: Is the MCINV6S the whole drive or only the control part?
A: It is the control module. The power stage is a separate unit, connected through CN1-LINK at 0-900 VDC and CN2 at 220-480 VAC three-phase. The module also takes the HALL current sensor on CN3 and sends the IGBT drive signals through CN9 and CN11. For a regenerative ACCORD drive, a second MCINV is synchronised over the RS-485 port on CN14.
Q2: What does it replace, and what has to change with it?
A: TKE lists it as a replacement for MCINV4 and MCINV5SL in installations already in service. The CAN lead to the MCP7S is a different cable, and the DAQ adapter is now 3Z.0565.DR.1. The ABENCI and INT5SL boards are no longer used, since both encoder inputs and the linear limit connection sit on this module.
Q3: Which encoders does it take?
A: Two, and both are on the board: CN6 for the incremental encoder, used on asynchronous machines and on MGR, and CN17, a DB15 for the absolute encoder on synchronous machines. That is the change from MCINV5SL, which needed the ABENCI module for that job. The load cell connects on CN8, and it is what feeds the weighing function.
Q4: How is the HALL sensor configured?
A: With jumpers JP1 to JP3 on the module, matched to the current rating of the power unit. For 100 A, 200 A and 500 A units all three stay open, for 125 A they go to position 2-3, and for 300 A to position 1-2. The configuration is read back through CN3, which is how the maximum rated current in the TLS menu is limited.
Q5: Does it cover the newer safety requirements?
A: Yes. TKE states that this module meets the NM207 requirements, which brought in double brake control and monitoring of the safety signals. Those signals arrive on CN13: pit, run, safety circuit, brake contacts, PTC and the door lock relay. A safety contactor that has tripped is reported as code CD on the display.
Q6: What should I send with the request?
A: A photo of the module label with the MCINV6S marking and the code, and a photo of the power unit rating plate. Whether the installation uses CAN or the INT6S parallel signals, and the encoder type on the machine. The firmware or site personality, because a module and controller with mismatched personalities report code CE.