説明
製品情報
関連モデルおよび代替モデル
Other GECB-EN versions:
- GBA26800LC1 — complete version, three series line terminals
- GBA26800LC3 — no door bypass, no TUEV switches
- GBA26800LC4 — no door bypass, no EPO
- GBA26800LC5 — LC2 with different F1 and F2 fuses
Boards fitted with it:
- AAA26800AML — GECB-CP central memory board
- DAA26800AY — GECB-AP board
- GCA26800NR — GECB-LV board
- GBA26800NK — LCB_IIC board
Potensi supplies the Otis elevator control board GBA26800LC2, the Otis GECB-EN PCB board and other Otis controller boards. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
ポテンシを選ぶ理由
- 99% の市場カバレッジ: 弊社では、市場で入手可能なエレベーター用スペアパーツを約99%分供給可能です。.
- 確かな品質保証: 当社は、純正で信頼性の高いエレベーター用部品を提供しています。.
- 専門家による身元確認の支援: 型番または製品の写真をお送りいただければ、適切な部品をご案内いたします。.
- 国際配送: 当社は、エレベーターの保守プロジェクトにおいて、迅速かつ確実な国際配送をサポートしています。.
よくある質問
Q1: What does the GBA26800LC2 board do?
A: It is the GECB-EN control board of the Otis controller cabinet, in the LC2 version. It handles the discrete inputs and outputs of the lift, the safety chain, door bypass, EPO and the TUEV switches. It provides the functions of the earlier TCBC board, GDA26800KA.
Q2: What is the difference between LC1, LC2, LC3 and LC5?
A: The seven GECB-EN versions are built for different applications, not for different lifts. LC1 is the complete version with three series line terminals. LC2 has door bypass, EPO, TUEV switches and one series line terminal. LC3 has no door bypass and no TUEV switches, and LC4 has no door bypass and no EPO. LC5 is the LC2 layout with different fuses for F1 and F2, so the two are not interchangeable on the fuse rating alone.
Q3: Is GAA26800LC2 or GCA26800LC2 the same board?
A: They belong to the same GECB-EN family but carry different assembly numbers, and the prefix is not a decoration. The Otis manual defines the seven versions as GBA26800LC1 to LC7, while the service tool documentation also refers to GCA26800LC as GECB-EN. Please read the full assembly number from your old board instead of comparing only the suffix, and send us a photo of the label.
Q4: I fitted a new board and the lift still does not run. Why?
A: The GECB-EN has no processor and no software of its own. All the control software and the parameters are held on the GECB-CP central memory board, AAA26800AML, which is a separate board. The CP board has to be moved over from the old unit or supplied with the correct software, otherwise the lift will not start.
Q5: Which Otis systems use this board?
A: It is used on Otis Gen2 and other GCS controllers of the GCS222 generation, and on ACD2 MRL systems with the SPBC drive panel. The board works with the SPBC through the PX5 connector and with the drive through the CAN interface on PX1. A photo of the cabinet and the board label is the fastest way to confirm the match.
Q6: What should be checked before fitting the board?
A: Check the six fuses on the board and the supply first, because a blown fuse or a short in the safety chain will damage a new board. The board is rated for a maximum of 125 V AC on the safety chain, and it is mounted on 16 insulated fixings. Please tell us the fault history and send photos, since several faults look the same from the controller.