説明
Product Information
関連モデルおよび代替モデル
Related TKE landing switches and leveling sensors in the same range:
- 3K5N-0185G01
- 3K5N-0185G02
- BUP-30S
- BUP-50S
3K5N-0185G01 and 3K5N-0185G02 are landing switches of the same series. BUP-30S and BUP-50S are leveling sensors used in TKE elevators. These models differ in type, mounting arrangement, sensing method, and connection, so the model, the pin assignment, and the mounting position must be confirmed against the original part.
The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.
ポテンシを選ぶ理由
- 99% の市場カバレッジ: 弊社では、市場で入手可能なエレベーター用スペアパーツを約99%分供給可能です。.
- 確かな品質保証: 当社は、純正で信頼性の高いエレベーター用部品を提供しています。.
- 専門家による身元確認の支援: 型番または製品の写真をお送りいただければ、適切な部品をご案内いたします。.
- 国際配送: 当社は、エレベーターの保守プロジェクトにおいて、迅速かつ確実な国際配送をサポートしています。.
よくある質問
Q1: What is the function of the SLD-4 landing switch?
A: It detects the car position at a landing and provides the leveling and door zone signals to the elevator control system. The signals are used for accurate stopping at the floor.
Q2: What are the electrical specifications of this switch?
A: Output type is PNP, dark on. Power supply is 24V DC, with a current of 300mA.
Q3: How is the SLD-4 wired?
A: It uses a 6-core cable with a 6-pin terminal block. Pin 1 is +24V (red), Pin 2 is GND (blue), Pin 3 is LU (yellow), Pin 4 is LD (black), Pin 5 is DZ1 (green), and Pin 6 is DZ2 (white).
Q4: How can I confirm whether this switch fits my elevator?
A: Please compare the model, the pin assignment, the mounting arrangement, the dimensions, and the connector with your original switch.
Q5: Can you help identify the correct switch if I am not sure?
A: Yes. Please send clear photos of the original switch, including the complete body, the part number or label, the mounting bracket, and the connector. Our technical team can help identify the correct part.
Q6: Do you supply other TKE landing switches and sensors?
A: Yes. We supply landing switches, leveling switches, leveling sensors, limit switches, and other TKE elevator switches and sensors.