{"id":8459,"date":"2026-11-23T08:19:03","date_gmt":"2026-11-23T08:19:03","guid":{"rendered":"https:\/\/potensilift.com\/?post_type=product&#038;p=8459"},"modified":"2026-11-23T08:40:31","modified_gmt":"2026-11-23T08:40:31","slug":"tke-inverter-control-module-mcinv6s","status":"publish","type":"product","link":"https:\/\/potensilift.com\/en\/product\/tke-inverter-control-module-mcinv6s\/","title":{"rendered":"TKE Inverter Control Module MCINV6S"},"content":{"rendered":"<h2 class=\"text-[1.2rem] font-bold mt-4 mb-2 text-zinc-800 dark:text-zinc-200 first:mt-0 tracking-tight\">Product Information<\/h2>\n<div class=\"my-5 relative flex-1 min-h-0 min-w-0 hover:cursor-default overflow-x-auto overflow-y-hidden phoenix-scrollbar\">\n<div>\n<table class=\"min-w-full border-collapse text-sm\">\n<thead>\n<tr>\n<th class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2 bg-zinc-50 dark:bg-zinc-800\/80 font-semibold text-left text-zinc-700 dark:text-zinc-300\">Feature<\/th>\n<th class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2 bg-zinc-50 dark:bg-zinc-800\/80 font-semibold text-left text-zinc-700 dark:text-zinc-300\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Model Number<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">MCINV6S (TKE code 3Z.0599.M-00)<\/td>\n<\/tr>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Also Written As<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">MCINV 6S, modulo de controle do inversor, inverter control module, TKE drive board, MCINV6-S<\/td>\n<\/tr>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Brand<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">TKE<\/td>\n<\/tr>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Product Type<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">Inverter control module (drive control board)<\/td>\n<\/tr>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Function<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">Motor control, encoder and limit reading, PWM to the power unit, CAN to MCP7S<\/td>\n<\/tr>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Used On<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">TKE lifts with MCP7S controllers and ACCORD regenerative drives<\/td>\n<\/tr>\n<tr>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Compatibility<\/strong><\/td>\n<td class=\"border border-zinc-200 dark:border-zinc-700 px-3 py-2\">Replaces MCINV4 and MCINV5SL; power unit and HALL setting must match<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr class=\"my-6 border-zinc-200\/80 dark:border-zinc-700\/80\" \/>\n<h2 class=\"text-[1.2rem] font-bold mt-4 mb-2 text-zinc-800 dark:text-zinc-200 first:mt-0 tracking-tight\">Related &amp; Alternative Models<\/h2>\n<p class=\"!mt-2 !mb-2 leading-relaxed\">The other MCINV modules, and the boards it connects to.<\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\">Other MCINV modules:<\/p>\n<ul class=\"my-2 space-y-1.5 leading-[1.85] pl-5\">\n<li class=\"leading-[1.85] pl-1\">MCINV5SL \u2014 previous version, replaced by MCINV6S<\/li>\n<li class=\"leading-[1.85] pl-1\">MCINV4 \u2014 earlier version, also replaced by MCINV6S<\/li>\n<li class=\"leading-[1.85] pl-1\">MCINV3 \u2014 earliest module of the range<\/li>\n<\/ul>\n<p class=\"!mt-2 !mb-2 leading-relaxed\">Modules it connects to:<\/p>\n<ul class=\"my-2 space-y-1.5 leading-[1.85] pl-5\">\n<li class=\"leading-[1.85] pl-1\">MCP7S \u2014 main controller board<\/li>\n<li class=\"leading-[1.85] pl-1\">INT6S \u2014 parallel signal interface module<\/li>\n<li class=\"leading-[1.85] pl-1\">MEED6S \u2014 magnetic limit module<\/li>\n<li class=\"leading-[1.85] pl-1\">M4RS \u2014 relay and signal expansion<\/li>\n<\/ul>\n<p class=\"!mt-2 !mb-2 leading-relaxed\">Potensi supplies the TKE inverter control module MCINV6S and the TKE MCINV drive range around it. The models above are only a part of what we can supply. We stock and source a much wider range of related and alternative models. If your model number is not listed here, please send us the model number or a photo of the original part, and we will confirm availability and the correct match for you.<\/p>\n<hr class=\"my-6 border-zinc-200\/80 dark:border-zinc-700\/80\" \/>\n<h2 class=\"text-[1.2rem] font-bold mt-4 mb-2 text-zinc-800 dark:text-zinc-200 first:mt-0 tracking-tight\">Why Choose Potensi?<\/h2>\n<ul class=\"my-2 space-y-1.5 leading-[1.85] pl-5\">\n<li class=\"leading-[1.85] pl-1\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">99% Market Coverage:<\/strong>\u00a0We can supply nearly 99% of elevator spare parts on the market.<\/li>\n<li class=\"leading-[1.85] pl-1\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Genuine Quality Assurance:<\/strong>\u00a0We provide genuine and reliable elevator components.<\/li>\n<li class=\"leading-[1.85] pl-1\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Expert Identification Support:<\/strong>\u00a0Send us the model number or product photos, and we can help confirm the correct part.<\/li>\n<li class=\"leading-[1.85] pl-1\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Global Shipping:<\/strong>\u00a0We support fast and reliable international delivery for elevator maintenance projects.<\/li>\n<\/ul>\n<hr class=\"my-6 border-zinc-200\/80 dark:border-zinc-700\/80\" \/>\n<h2 class=\"text-[1.2rem] font-bold mt-4 mb-2 text-zinc-800 dark:text-zinc-200 first:mt-0 tracking-tight\">FAQ<\/h2>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Q1: Is the MCINV6S the whole drive or only the control part?<\/strong><\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">A:<\/strong>\u00a0It is the control module. The power stage is a separate unit, connected through CN1-LINK at 0-900 VDC and CN2 at 220-480 VAC three-phase. The module also takes the HALL current sensor on CN3 and sends the IGBT drive signals through CN9 and CN11. For a regenerative ACCORD drive, a second MCINV is synchronised over the RS-485 port on CN14.<\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Q2: What does it replace, and what has to change with it?<\/strong><\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">A:<\/strong>\u00a0TKE lists it as a replacement for MCINV4 and MCINV5SL in installations already in service. The CAN lead to the MCP7S is a different cable, and the DAQ adapter is now 3Z.0565.DR.1. The ABENCI and INT5SL boards are no longer used, since both encoder inputs and the linear limit connection sit on this module.<\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Q3: Which encoders does it take?<\/strong><\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">A:<\/strong>\u00a0Two, and both are on the board: CN6 for the incremental encoder, used on asynchronous machines and on MGR, and CN17, a DB15 for the absolute encoder on synchronous machines. That is the change from MCINV5SL, which needed the ABENCI module for that job. The load cell connects on CN8, and it is what feeds the weighing function.<\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Q4: How is the HALL sensor configured?<\/strong><\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">A:<\/strong>\u00a0With jumpers JP1 to JP3 on the module, matched to the current rating of the power unit. For 100 A, 200 A and 500 A units all three stay open, for 125 A they go to position 2-3, and for 300 A to position 1-2. The configuration is read back through CN3, which is how the maximum rated current in the TLS menu is limited.<\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Q5: Does it cover the newer safety requirements?<\/strong><\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">A:<\/strong>\u00a0Yes. TKE states that this module meets the NM207 requirements, which brought in double brake control and monitoring of the safety signals. Those signals arrive on CN13: pit, run, safety circuit, brake contacts, PTC and the door lock relay. A safety contactor that has tripped is reported as code CD on the display.<\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">Q6: What should I send with the request?<\/strong><\/p>\n<p class=\"!mt-2 !mb-2 leading-relaxed\"><strong class=\"font-semibold text-zinc-900 dark:text-zinc-100\">A:<\/strong>\u00a0A photo of the module label with the MCINV6S marking and the code, and a photo of the power unit rating plate. Whether the installation uses CAN or the INT6S parallel signals, and the encoder type on the machine. The firmware or site personality, because a module and controller with mismatched personalities report code CE.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>MCINV6S, TKE code 3Z.0599.M-00, is the control module of the TKE lift drive: it handles motor control and safety signals and drives the power unit over the PWM and link connections. It reads incremental or absolute encoders, the load cell and the magnetic or linear limits, and talks to the MCP7S controller over CAN. It replaces MCINV4 and MCINV5SL in existing installations.<\/p>\n","protected":false},"featured_media":8460,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[57,26,161,129],"product_tag":[],"class_list":{"0":"post-8459","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-brands-parts","7":"product_cat-elevator-parts","8":"product_cat-elevator-pcb","9":"product_cat-for-tke-thyssenkrupp","11":"first","12":"instock","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/product\/8459"}],"collection":[{"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/comments?post=8459"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/media\/8460"}],"wp:attachment":[{"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/media?parent=8459"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/product_brand?post=8459"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/product_cat?post=8459"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/potensilift.com\/en\/wp-json\/wp\/v2\/product_tag?post=8459"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}